本课属于 Coddy PLC Programming 学习旅程的“模拟量与顺序控制”单元。第 9 课,共 17 课。

一个批次是完整运行一次这个流程:填充、混合、排空,然后回到空闲状态,准备好开始下一个批次。

最后一步会排空储罐,直到储罐为空。这里仅靠 Low 开关不够:储罐还剩四分之一批次时,它就会变为 FALSE。改用模拟输入:在这个储罐中,储罐为空时 Level 的读数为 0。实际的变送器很少会恰好读数为 0,因此实际程序通常会与一个较小的数值进行比较,你将在第 6 单元中这样做。

机器会统计每个已填充到 High、随后又排空的批次。

challenge icon

挑战

困难
  • 混合完成后,将 3 移入 Step,而不是 0
  • 在第 3 步中,打开 Drain
  • 当 Level 的读数为 0 时,将 0 移入 Step

亲手试试

{"v":1,"lang":"ld","tags":[{"name":"Step","type":"INT"},{"name":"T1","type":"TON"}],"rungs":[{"els":[{"t":"cmp","op":"EQ","a":"Step","b":0},{"t":"no","tag":"Start"},{"t":"move","src":1,"dst":"Step"}]},{"els":[{"t":"cmp","op":"EQ","a":"Step","b":1},{"t":"no","tag":"High"},{"t":"move","src":2,"dst":"Step"}]},{"els":[{"t":"cmp","op":"EQ","a":"Step","b":2},{"t":"TON","inst":"T1","pt":"T#5s"},{"t":"move","src":0,"dst":"Step"}]},{"els":[{"t":"cmp","op":"EQ","a":"Step","b":1},{"t":"coil","tag":"Fill"}]},{"els":[{"t":"cmp","op":"EQ","a":"Step","b":2},{"t":"coil","tag":"Mixer"}]}]}

模拟量与顺序控制中的所有课