Counters in Text
Part of the Structured Text section of Coddy's PLC Programming journey. Lesson 8 of 17.
Counters are blocks too. A CTU takes CU (count up), R (reset) and PV (the preset), and gives CV (the count) and Q (CV has reached PV):
VAR
C1 : CTU;
END_VAR
C1(CU := Entry, PV := 6);
Display := C1.CV;The CU input counts rising edges on its own: a box that blocks the eye for 80 scans counts once. A CTD counts down the same way, with CD, LD and PV.
The belt runs from a seal-in, already written for you as the first statement.
Challenge
Easy- Count the boxes that pass the
Entryeye with a CTU. - Show the count on
Display. - Light
Lampwhen 6 boxes have passed.
Press Run, try it on the machine, then Check.
Try it yourself
VAR
C1 : CTU;
END_VAR
Belt := (Start OR Belt) AND Stop;
// Count boxes on Entry, then Display and Lamp
All lessons in Structured Text
Practice on your own: PLC playground