TOF and TP in Text
Part of the Structured Text section of Coddy's PLC Programming journey. Lesson 7 of 17.
The other two timers are called the same way, with IN and PT. Only the type changes:
TOF: Q turns on with IN and stays on for PT after IN turns off (off-delay).TP: a rising IN starts a pulse; Q stays on for exactly PT, however long IN is held.
VAR
RunOn : TOF;
Beep : TP;
END_VAR
RunOn(IN := PB1, PT := T#3s);
Amber := RunOn.Q;Give each timer its own name. One instance is one timer: it holds its own time between scans, so two jobs need two instances.
Challenge
EasyAmberlights withPB1and stays lit 3 s after it is released.- Each press of
PB2soundsHornfor exactly 1 s, short tap or long hold.
Try it yourself
VAR
RunOn : TOF;
Beep : TP;
END_VAR
// The run-on for Amber
// The beep for Horn
All lessons in Structured Text
Practice on your own: PLC playground