A Batch of Six

Part of the Counters and Numbers section of Coddy's PLC Programming journey. Lesson 12 of 17.

Boxes are packed in batches of six. The belt should stop by itself when the sixth box reaches the Eye, and Start should begin the next batch.

Set the counter's PV to 6. Its Q turns TRUE on the sixth box, so a normally closed contact on C1.Q in the belt's rung breaks the seal-in. Give the counter R = Start: pressing Start clears the count, Q goes off, and the belt can run again. Every Start clears the count, even one in the middle of a batch, so a Stop part way through starts that batch over.

challenge icon

Challenge

Medium
  • set the counter's PV to 6 and its R to Start
  • add a normally closed contact on C1.Q to the belt's rung

The belt should stop on the sixth box, and Start should run a new batch.

Try it yourself

{"v":1,"lang":"ld","tags":[{"name":"C1","type":"CTU"}],"rungs":[{"els":[{"t":"par","branches":[[{"t":"no","tag":"Start"}],[{"t":"no","tag":"Belt"}]]},{"t":"no","tag":"Stop"},{"t":"coil","tag":"Belt"}]},{"els":[{"t":"no","tag":"Belt"},{"t":"coil","tag":"Lamp"}]},{"els":[{"t":"no","tag":"Eye"},{"t":"CTU","inst":"C1","pv":9999,"r":""}]},{"els":[{"t":"move","src":"C1.CV","dst":"Display"}]}]}