Run-On Cooling Fan

Part of the Timers section of Coddy's PLC Programming journey. Lesson 7 of 18.

A hot machine should not lose its cooling the moment it stops. The fan runs while the machine runs and keeps running a few seconds after: a run-on.

That is a TOF on the machine's own output. While the machine runs, the fan runs. When it stops, the fan runs on for PT.

On this panel, Green stands for the machine and Blue for its cooling fan. PB1 starts the machine and PB2 stops it.

challenge icon

Challenge

Easy

Rung 1 runs the machine (Green). Add a rung so the fan (Blue) runs while Green is on and keeps running 5 s after the machine stops.

Try it yourself

{"v":1,"lang":"ld","tags":[],"rungs":[{"els":[{"t":"par","branches":[[{"t":"no","tag":"PB1"}],[{"t":"no","tag":"Green"}]]},{"t":"nc","tag":"PB2"},{"t":"coil","tag":"Green"}]},{"els":[]}]}